C349 Base light

If you unable to resolve the issue, log in to http://myUR.universal-robots.com and create a new case.

C349A0 Length check error, incorrect length detected for base light ring: {unsigned}

The detected lenght of the base light ring is not what is expected.

There is an issue validating the base light. If problem persists, contact your local Universal Robots service provider for assistance.

C349A2 Current for the red color was {float} A, which is outside the allowed range

The detected current of the red color in the base light is outside the allowed range.

Try the following actions to see which resolves the issue: (A) Perform a complete rebooting sequence, (B) Update software, (C) Check if the connection between the light ring and the PCB is correct, (D) Replace The light ring, (E) Contact your local Universal Robots service provider for assistance

C349A3 Current for the green color was {float} A, which is outside the allowed range

The detected current of the green color in the base light is outside the allowed range.

Try the following actions to see which resolves the issue: (A) Perform a complete rebooting sequence, (B) Update software, (C) Check if the connection between the light ring and the PCB is correct, (D) Replace The light ring, (E) Contact your local Universal Robots service provider for assistance

C349A4 Current for the blue color was {float} A, which is outside the allowed range

The detected current of the blue color in the base light is outside the allowed range.

Try the following actions to see which resolves the issue: (A) Perform a complete rebooting sequence, (B) Update software, (C) Check if the connection between the light ring and the PCB is correct, (D) Replace The light ring, (E) Contact your local Universal Robots service provider for assistance

C349A5 Current for the yellow color was {float} A, which is outside the allowed range

The detected current of the yellow color in the base light is outside the allowed range.