C340 Energy Monitoring

If you unable to resolve the issue, log in to http://myUR.universal-robots.com and create a new case.

C340A0 Idle power consumption too high

The system is drawing more power than expected while idle

Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Check Energy Eaters cable and connections, (C) Check Energy Eater, (D) Update software, (E) Contact your local Universal Robots service provider for assistance

C340A1 Energy surplus shutdown

The power supply is sending energy to the energy eater

Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Update software, (C) Contact your local Universal Robots service provider for assistance

C340A2 Energy burst period exceeded, average power: {float}W

Energy has been sent to the energy eater longer than allowed

Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Update software, (C) Contact your local Universal Robots service provider for assistance