C330 IMMI IO
If you unable to resolve the issue, log in to http://myUR.universal-robots.com and create a new case.
C330A1 Injection-Molding-Machine-Interface E-Stop output readback does not match produced value: {hex}
First byte: produced value, second byte: read value
C330A2 Injection-Molding-Machine-Interface Moulding Area Free output readback does not match produced value: {hex}
First byte: produced value, second byte: read value
C330A3 Injection-Molding-Machine-Interface 24V IO voltage outside acceptable range
The voltage measured on the 24V IO rail is lower than expected.
Try the following actions to see which resolves the issue: (A) Check the fuses on the Injection-Molding-Machine-Interface. (B) Verify there are no short circuits on the 24V IO connectors. (C) Contact your local Universal Robots service provider for assistance.
C330A4 Injection-Molding-Machine-Interface 48V voltages outside acceptable range
The voltages measured on the 48V rails are lower than expected.
Try the following actions to see which resolves the issue: (A) Check the fuses on the Injection-Molding-Machine-Interface. (B) Verify there are no short circuits on the IO connectors. (C) Contact your local Universal Robots service provider for assistance.