Skip To Main Content
Account
Settings
Logout
placeholder
Account
Settings
Logout
Filter:
All Files
Submit Search
PolyScope 5 Software Handbook
Robot User Manuals
Script Directory
Introduction
Connecting to URControl
Numbers, Variables, and Types
Lists and Structs
Matrix and Array Expressions
Flow of Control
Function
Remote Procedure Call (RPC)
Scoping rules
Threads
Program Label
Secondary Programs
Interpreter Mode
Motion Version
Module motion
Module internals
Module urmath
Module interfaces
enable_external_ft_sensor(enable, sensor_mass=0.0, sensor_measuring_offset=[0.0, 0.0, 0.0], sensor_cog=[0.0, 0.0, 0.0])
ft_rtde_input_enable(enable, sensor_mass=0.0, sensor_measuring_offset=[0.0, 0.0, 0.0], sensor_cog=[0.0, 0.0, 0.0])
get_analog_in(n)
get_analog_out(n)
get_configurable_digital_in(n)
get_configurable_digital_out(n)
get_digital_in(n)
get_digital_out(n)
get_flag(n)
get_rtde_value(key)
get_standard_analog_in(n)
get_standard_analog_out(n)
get_standard_digital_in(n)
get_standard_digital_out(n)
get_tool_analog_in(n)
get_tool_digital_in(n)
get_tool_digital_out(n)
modbus_add_signal(IP, slave_number, signal_address, signal_type, signal_name, sequential_mode=False, register_count=1)
modbus_add_rw_signal(IP, slave_number, read_address, read_register_count, write_address, write_register_count, signal_name, sequential_mode=False)
modbus_delete_signal(signal_name)
modbus_get_signal_status(signal_name, is_secondary_program=False)
modbus_send_custom_command(IP, slave_number, function_code, data)
modbus_set_digital_input_action(signal_name, action)
modbus_set_output_register(signal_name, register_value, is_secondary_program=False)
modbus_set_output_signal(signal_name, digital_value, is_secondary_program, False)
modbus_set_signal_update_frequency(signal_name, update_frequency)
modbus_get_error(signal_name)
modbus_get_time_since_signal_invalid(signal_name)
modbus_request_update_signal_value(signal_name)
modbus_reset_connection(connection_id, is_blocking=True)
modbus_set_signal_watchdog(signal_name, new_timeout_in_sec)
read_input_boolean_register(address)
read_input_float_register(address)
read_input_integer_register(address)
read_output_boolean_register(address)
read_output_float_register(address)
read_output_integer_register(address)
read_port_bit(address)
read_port_register(address)
rpc_factory(type, url)
rtde_set_watchdog(variable_name, min_frequency, action=’pause’)
set_analog_inputrange(port, range)
set_analog_out(n, f )
set_configurable_digital_out(n, b)
set_digital_out(n, b)
set_flag(n, b)
set_standard_analog_out(n, f)
set_standard_digital_out(n, b)
set_tool_digital_out(n, b)
set_tool_communication(enabled, baud_rate, parity, stop_bits,
set_tool_digital_output_mode (n, mode)
set_tool_output_mode (mode)
set_tool_voltage(voltage)
socket_close(socket_name=’socket_0’)
socket_get_var(name, socket_name=’socket_0’)
socket_open(address, port, socket_name=’socket_0’)
socket_read_ascii_float(number, socket_name=’socket_0’, timeout=2)
socket_read_binary_integer(number, socket_name=’socket_0’, timeout=2)
socket_read_byte_list(number, socket_name=’socket_0’, timeout=2)
socket_read_line(socket_name=’socket_0’, timeout=2)
socket_read_string(socket_name=’socket_0’, prefix =’’, suffix =’’, interpret_escape=’False’, timeout=2)
socket_send_byte(value, socket_name=’socket_0’)
socket_send_int(value, socket_name=’socket_0’)
socket_send_line(str, socket_name=’socket_0’)
socket_send_string(str, socket_name=’socket_0’)
socket_set_var(name, value, socket_name=’socket_0’)
write_output_boolean_register(address, value)
write_output_float_register(address, value)
write_output_integer_register(address, value)
write_port_bit(address, value)
write_port_register(address, value)
zero_ftsensor()
request_boolean_from_primary_client(message)
Module ioconfiguration
Module processpath
Flexible Ethernet/IP Adapter
Service Your Robot
Components For Your Robot
Kits For Your Robot
Application Guides
Software Guides
Filter:
All Files
Submit Search
You are here: