Update Files are not shown on Polyscope 5.12.8 Troubleshooting
An escaped defect in PolyScope 5.12.8 hides valid update files. A magic script corrects it, so the robot can be updated as usual.
Product(s) affected: Robots running PolyScope 5.12.8
Issue description
On PolyScope 5.12.8, a valid software update file on the USB stick is left out when you search for updates. The update screen looks as if there is no update available.
Cause
This is an escaped defect in PolyScope 5.12.8. The correction must be applied on the robot before an update file is listed. A magic script applies this correction. After the script has finished, updates are shown correctly and the robot can be updated.
Before you start
Magic files are disabled by default. Enable them only for this procedure, and disable them again when the script has finished.
How to run the magic script
- In the header, tap the hamburger menu and select Settings.
- Under Security, select General.
- Enter the admin password.
- Enable Run Magic Files.
- Download the magic script urmagic-fix-urup-ranges.sh.
- Save the script in the root folder of a USB stick. Keep this script alone in that folder, so no other magic file runs with it.
- Insert the USB stick into the USB slot in the control box.
- A red !USB! sign appears on the screen. Leave the USB stick in place.
- Wait until a green <-USB sign appears, then remove the USB stick.
- Open Settings, Security, General again and disable Run Magic Files.
Result
The update files are now shown correctly, and the robot can be updated.