C340 Energy Monitoring
If you unable to resolve the issue, log in to http://myUR.universal-robots.com and create a new case.
C340A0 Idle power consumption too high
The system is drawing more power than expected while idle
Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Check Energy Eaters cable and connections, (C) Check Energy Eater, (D) Update software, (E) Contact your local Universal Robots service provider for assistance
C340A1 Energy surplus shutdown
The power supply is sending energy to the energy eater
Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Update software, (C) Contact your local Universal Robots service provider for assistance
C340A2 Energy burst period exceeded, average power: {float}W
Energy has been sent to the energy eater longer than allowed
Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Update software, (C) Contact your local Universal Robots service provider for assistance
C340A3 The Energy Removal Device peak power exceeded
The absolute limit for the Energy Removal Device has been exceeded
Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Update software, (C) Contact your local Universal Robots service provider for assistance
C340A4 The Energy Removal Device drew too much power over a period
The power drawn by the Energy Removal Device over a period has exceeded the allowed limit
Try the following actions to see which resolves the issue: (A) Ensure supply is not delivering more than 48V, (B) Update software, (C) Contact your local Universal Robots service provider for assistance