Replacing the 3PE Teach Pendant
This section describes how to replace a Standard Teach Pendant with a 3PE Teach Pendant. For information on how to remove and replace a Standard Teach Pendant, see Replacing the Teach Pendant: Standard TP
-
Power down the control box and disconnect the main power cable from the power source.
-
If mounted, remove the ferrite core with snap lock from the teach pendant cable by cutting the cable ties of key.
|
|
-
Insert the key into the ferrite core with snap lock to unlock it and remove it.
-
Remove and discard the two cable ties used for mounting the Teach Pendant cables.
-
Press in the clips on both sides of the Teach Pendant plug, as illustrated, and pull down to disconnect from the Teach Pendant port.
-
Fully open/loosen the plastic grommet at the bottom of the Control Box and remove the Teach Pendant plug and cable.
-
Gently remove the Teach Pendant cable and Teach Pendant.