Replacing the 3PE Teach Pendant

This section describes how to replace a Standard Teach Pendant with a 3PE Teach Pendant. For information on how to remove and replace a Standard Teach Pendant, see Replacing the Teach Pendant: Standard TP

  1. Power down the control box and disconnect the main power cable from the power source.

  2. If mounted, remove the ferrite core with snap lock from the teach pendant cable by cutting the cable ties of key.

  1. Insert the key into the ferrite core with snap lock to unlock it and remove it.

  1. Remove and discard the two cable ties used for mounting the Teach Pendant cables.

  2. Press in the clips on both sides of the Teach Pendant plug, as illustrated, and pull down to disconnect from the Teach Pendant port.

  3. Fully open/loosen the plastic grommet at the bottom of the Control Box and remove the Teach Pendant plug and cable.

  4. Gently remove the Teach Pendant cable and Teach Pendant.