C201 Setup of Safety Control Board failed

You may find the following links helpful in addressing this issue:

If you unable to resolve the issue, log in to http://myUR.universal-robots.com and create a new case.

C201A0 Setup of Safety Control Board failed

No data was received from the Safety Control Board at initialization or invalid safety parameters have been received

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Check that the ethernet cable between Motherboard and Safety Control Board is connected and verify that the setup of the Safety Configuration is valid.

C201A1 SCB uA is not responding

No data or invalid data was received from the Safety Control Board uA at initialization

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Check that the ethernet cable between Motherboard and Safety Control Board is connected and verify that the setup of the Safety Configuration is valid.

C201A2 SCB uB is not responding

No data or invalid data was received from the Safety Control Board uB at initialization

Conduct a complete rebooting sequence.

C201A3 SCB is not responding

No data or invalid was received from Safety Control Board when requested for configuration parameters

Conduct a complete rebooting sequence.