C74 Joint encoder warning

Magnetic encoder error (absolute encoder). Argument = sum of C74 errors

C74A1 Invalid decode: Readhead misalignment, ring damaged or external magnetic field present.

Check grounding and shielding for EMC problems

C74A2 Speed reading is not valid

C74A4 System error=malfunction or inconsistent calibration detected

C74A8 Supply voltage is out of range

C74A16 Temperature is out of range

C74A32 Signal lost =Misaligned readhead or damaged ring

C74A64 Signal low =Too far from magnetic ring

C74A128 Signal saturation =Too close to magnetic ring

If you unable to resolve the issue, login to http://myUR.universal-robots.com and create a new case.