C309 Keep-Alive System

C309A0 Critical error

A critical error occurred in the Keep-Alive System

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software

C309A1 Keep-Alive System message with wrong sequence received from SCB-uPA.

C309A2 Timeout reached while waiting for a Keep-Alive System message from SCB-uPA.

C309A3 Go-to-Fault command received a Keep-Alive System message from SCB-uPA.

C309A4 A Keep-Alive System message with wrong sequence received from SCB-uPB.

C309A5 Timeout reached while waiting for Keep-Alive System message from SCB-uPB.

C309A6 Go-to-Fault command received in Keep-Alive System message from SCB-uPB.

C309A7 Keep-Alive System message received from an unauthorized source: {unsigned}

C309A8 uPA handler received an invalid value

C309A9 uPB handler received an invalid value

C309A10 Lost {unsigned} Keep-Alive System message(s) in a row from Safety Control Board-uPA

An invalid amount of Keep-Alive System messages have been lost from the Safety Control Board Processor A

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software

C309A11 Lost {unsigned} Keep-Alive System message(s) in a row from Safety Control Board-uPB

A invalid amount of Keep-Alive messages have been lost from the Safety Control Board Processor B

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software

C309A12 Go-to-Violation command received in Keep-Alive System message from SCB-uPA.

C309A13 Go-to-Violation command received in Keep-Alive System message from SCB-uPB.

C309A14 Invalid command received in Keep-Alive System message from SCB-uPA.

C309A15 Invalid command received in Keep-Alive System message from SCB-uPB.

If you are unable to resolve the issue, login or create an account at http://myUR.universal-robots.com and post a new ticket.