C303 System status

C303A0 Critical error

A critical system error occurred

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software

C303A1 Starting up

C303A2 Shutting down

C303A3 Reset caused by unknown reasons

C303A4 Reset caused by power loss

C303A5 Reset caused by window watchdog

C303A6 Reset caused by independent watchdog

C303A7 Reset caused by software

C303A8 Reset caused by power on

C303A9 Reset caused by reset pin

C303A10 Reset caused by brown out

C303A11 Reset caused by a loss of lock in the PLL

C303A12 Reset caused by a loss of external clock.

C303A13 Reset caused by LLWU module wakeup source

C303A14 Reset caused by peripheral failure to acknowledge attempt to enter Stop Mode

C303A15 Reset caused by EzPort receiving the RESET command while the device is in EzPort mode

C303A16 Reset caused by host debugger system setting of the System Reset Request bit

C303A17 Reset caused by core LOCKUP event

C303A18 Reset caused by JTAG

C303A19 Unexpected core frequency configured: {unsigned}

If you are unable to resolve the issue, login or create an account at http://myUR.universal-robots.com and post a new ticket