C305 Robot Power Control

C305A0 Critical error

A critical error in power control module, supply voltage is >50V

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software,

C305A1 Power supply voltage too low

Try the following actions to see which resolves the issue: (A) Check for loose connections, (B) Conduct a complete rebooting sequence, (C) Update software,

C305A2 Robot cable not connected

Try the following actions to see which resolves the issue: (A) Make sure the cable between Control Box and Robot Arm is correctly connected and it has no damage, (B) Check for loose connections, (C) Conduct a complete rebooting sequence, (D) Update software,

C305A3 Short circuit in Robot detected or the wrong Robot is connected to the Control Box.

Try the following actions to see which resolves the issue: (A) Check for loose connections, (B) Make sure the cable between Control Box and Robot Arm is correctly connected and it has no damage, (C) Conduct a complete rebooting sequence, (D) Update software,

C305A4 Robot voltage rising slower than expected

Try the following actions to see which resolves the issue: (A) Verify the power supply, (B) Verify Control Box and Robot Arm are correctly paired,

C305A5 Attempted to start Energy Eater with powered robot

C305A6 Power supply voltage too high: {float} V

Try the following actions to see which resolves the issue: (A) Check for loose connections, (B) Make sure the cable between Control Box and Robot Arm is correctly connected and it has no damage, (C) Conduct a complete rebooting sequence, (D) Update software,

C305A7 Energy Eater was active when trying to turn on the Robot arm

C305A8 The Robot Voltage is too high ({float})V when powering on the Robot

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software,

C305A9 The Power State was not OFF ({unsigned}) when trying to power on the Robot

Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software,

C305A10 The Delay Callback setup failed at the {unsigned} stage

C305A11 The power to the robot arm was not removed fast enough after violation

 

If you are unable to resolve the issue, login or create an account at http://myUR.universal-robots.com and post a new ticket.