C299 Tool communication
C299A0 Communication error detected
A problem with the Tool communication was detected.
Try the following actions to see which resolves the issue: (A) Conduct a complete rebooting sequence, (B) Update software
C299A1 TX buffer overflow
The output buffer of the tool has overflown
C299A2 New message started unexpectedly
A new message started before all data from previous message was received
C299A3 RX framing error
Framing error detected on received data
Try the following actions to see which resolves the issue: (A) Check external equipment connection, (B) Verify the communication configuration matches the hardware, (C) Conduct a complete rebooting sequence, (D) Update software
C299A4 RX Parity error
Parity error detected on received data
Try the following actions to see which resolves the issue: (A) Check external equipment connection, (B) Verify the communication configuration matches the hardware, (C) Conduct a complete rebooting sequence, (D) Update software
C299A5 RX buffer overflow.
The input buffer has overflown
If you are unable to resolve the issue, login or create an account at http://myUR.universal-robots.com and post a new ticket